Traduciendo...
F109-44

Plausibility fault in encoder interface (A3401 = encoder 1 and A3402 = encoder 2)

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

¿Qué significa F109-44 ?

The encoder interface (A3401 or A3402) does not match the configured data. This suggests a mismatch between the physical encoder type/connection and the drive's settings.

Causas comunes

  • Encoder data stream indicates a deviation from expected patterns.
  • Mismatch in position or velocity feedback from encoder 1 (A3401) or encoder 2 (A3402).
  • Faulty encoder communication protocol interpretation.
  • Environmental interference corrupting encoder signals.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check encoder type and configuration (SSI/incremental).

  2. 2

    Check the encoder connection/wiring.

  3. 3

    Check the polarity of the encoder data.

  4. 4

    Check function of the encoder.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: SEW Eurodrive MOVIDRIVE MDX60B/61B Variable Speed Drive