Traduciendo...
F109-164

Plausibility fault - SSI encoder connection (master mode)

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

¿Qué significa F109-164 ?

The connected encoder type does not correspond to the configuration for an SSI encoder operating in master mode. This indicates a mismatch in setup.

Causas comunes

  • Faulty SSI encoder connection in master mode.
  • Incorrect wiring of SSI encoder signals (clock, data).
  • Parameter P0205 setting for SSI master mode incorrect.
  • SSI encoder data transmission errors or timeout.
  • Clock signal issue from the master drive to the SSI encoder.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check encoder connection and cabling.

  2. 2

    Check the connected encoder.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas