42

Lag Error

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

¿Qué significa 42 ?

Immediate switch-off because the actual position or speed of the motor is lagging too far behind its setpoint. Possible causes include an incorrectly connected encoder, overly short acceleration ramps, a P component of the positioning controller that is too small, incorrectly set speed controller parameters, a lag fault tolerance value that is too small, or mechanical binding in the system.

Causas comunes

  • The actual motor speed or position is lagging significantly behind the commanded value.
  • Low motor torque or excessive load preventing speed following.
  • PID controller tuning is inadequate for the application dynamics.
  • Inaccurate feedback signal causing perceived lag.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the encoder connection for integrity and correct wiring.

  2. 2

    Extend the acceleration/deceleration ramps to reduce demand on the motor and controller.

  3. 3

    Set the P component (proportional gain) of the positioning controller to a higher value.

  4. 4

    Reset or finely tune speed controller parameters.

  5. 5

    Increase the lag fault tolerance value (e.g., P703, P704 for positioning tolerance).

  6. 6

    Check the wiring of the encoder, motor, and mains phases.

Ver todos los códigos en este manual (78)