Traduciendo...
39
Reference Travel Error
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
¿Qué significa 39 ?
Immediate switch-off during reference travel because the reference cam is missing or not switching correctly, limit switches are connected incorrectly, or the reference travel type was changed while the process was active. This prevents the drive from accurately establishing its home position.
Causas comunes
- Error during the reference travel (homing) sequence.
- Reference switch not detected or signal unstable during homing.
- Motor moved in the wrong direction during homing.
- Configuration parameters for reference travel are incorrect.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the reference cam for presence and proper switching functionality.
- 2
Verify the limit switch connections are correct.
- 3
Check the reference travel type setting and all required parameters for consistency and ensure no changes during active travel.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)