29

Limit Switch Contacted (IPOS)

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

¿Qué significa 29 ?

Emergency stop indicating that a physical limit switch was reached while the drive was operating in IPOS mode. This suggests the programmed movement exceeded the defined mechanical travel range.

Causas comunes

  • Limit switch is activated during an Integrated Positioning (IPOS) operation.
  • Physical limit switch tripped unexpectedly during movement.
  • IPOS target position is beyond a physical limit switch.
  • Configuration conflict between IPOS and limit switch settings.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the configured travel range parameters in the IPOS program.

  2. 2

    Correct the IPOS operator program to ensure target positions remain within the defined limits.