Traduciendo...
12
Resolver 14-bit
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
¿Qué significa 12 ?
Emergency stop occurs because 14-bit resolver evaluation is active, and the actual motor speed exceeds 3600 1/min. The resolver feedback system is not designed for accurate operation above this speed.
Causas comunes
- The resolver feedback system is not providing valid or consistent positional data.
- Faulty resolver or resolver interface board.
- Signal interference or connection issues with the resolver wiring.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Set parameter P302 (Maximum speed 1) to a maximum value of 3600 1/min.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)