10

IPOS Invalid Operation

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

¿Qué significa 10 ?

Emergency stop caused by an incorrect command detected during the execution of the IPOS plus® program, incorrect conditions for command execution, or an attempt to use a function not supported by the inverter. This points to a logical error in the PLC program.

Causas comunes

  • Invalid operation detected within the IPOS (Integrated Programmable Output System).
  • Program error or incorrect command sequence in the programmable logic.
  • Conflict between different control functions managed by IPOS.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the content of the program memory for the IPOS program and correct any identified errors.

  2. 2

    Load the correct IPOS program into the program memory.

  3. 3

    Review the IPOS program sequence and logic, referring to the IPOS manual for detailed guidance.

  4. 4

    Modify the IPOS program to use a different, supported function if the current one is unavailable.

Ver todos los códigos en este manual (78)