001C
Controller inhibit required
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
¿Qué significa 001C ?
This PROFIBUS-DP additional code (Error Class 8, 'Other Error') means an attempted parameter change requires the drive inverter to be in a 'controller inhibit' state before modification can be applied. The inverter is currently enabled, preventing the parameter change.
Causas comunes
- A global controller inhibit signal is active, preventing operation or parameter changes.
- An external safety or control signal is preventing modification.
- The system requires an explicit enable command before allowing parameter updates.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.
Datos técnicos verificados. Última actualización: March 2026