0011

Function / parameter not implemented

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

¿Qué significa 0011 ?

This PROFIBUS-DP additional code (Error Class 8, 'Other Error') indicates a function or parameter requested via the parameter channel is not supported by the drive inverter's current configuration or hardware. This highlights a mismatch between the requested functionality and the inverter's capabilities.

Causas comunes

  • The specified function or parameter is not supported by the current firmware version.
  • Hardware configuration does not enable the requested function/parameter.
  • A feature has been removed or disabled in a software update.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.