Traduciendo...
104

Oil aging/over-temperature Display error

SEW Eurodrive · MCBSM

¿Qué significa 104 ?

The oil aging sensor signals an over-temperature condition in the gear unit oil. High oil temperatures accelerate degradation, reduce lubrication effectiveness, and can cause damage to the gear unit components and seals.

Causas comunes

  • Inadequate cooling of the gear unit due to clogged cooling fins, blocked ventilation, or cooling fan failure.
  • Overloading of the gear unit beyond its rated thermal capacity (e.g., continuous operation at 120% rated torque).
  • Incorrect lubricant type or viscosity used, leading to higher internal friction and excessive heat generation.
  • Increased internal friction due to worn bearings, misaligned gears, or critically insufficient lubrication levels.
  • High ambient operating temperature (e.g., above 40°C) exceeding the gear unit's design limits for heat dissipation.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    1. Measure the external surface temperature of the gearbox housing using an infrared thermometer (e.g., target temperature <70°C).

  2. 2

    2. Verify the functionality of any cooling fans or systems associated with the gear unit; clean or replace as needed.

  3. 3

    3. Confirm that the correct type and viscosity of oil are used, comparing to the nameplate or manual (e.g., ISO VG 320 for specific ambient conditions).

  4. 4

    4. Reduce the mechanical load on the gear unit to within its rated torque capacity (e.g., monitor via P2-01 Actual Torque).

  5. 5

    5. Check the oil level in the gearbox; add recommended oil if below the specified minimum mark on the dipstick or sight glass.

Ver todos los códigos en este manual (50)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas