Traduciendo...
103

Oil aging/fault Display error

SEW Eurodrive · MCBSM

¿Qué significa 103 ?

The oil aging sensor signals a fault, indicating that the gear unit oil has degraded to a critical level. Continued operation with aged oil can lead to premature wear of gears and bearings, increased friction, and eventual gear unit failure.

Causas comunes

  • Severe and prolonged operation beyond the oil's useful life without replacement, leading to critical viscosity loss.
  • Significant thermal stress causing rapid oxidation and breakdown of the oil's additives, resulting in acid formation.
  • Extensive contamination of the oil (e.g., water ingress >500 ppm), drastically reducing lubrication and protective properties.
  • Mechanical wear within the gearbox generating excessive metallic particles (e.g., >100 ppm iron), accelerating oil degradation.
  • Failure of the oil aging sensor itself, providing an erroneous critical fault signal (e.g., internal component failure).

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    1. Immediately cease operation of the gear unit to prevent further mechanical damage.

  2. 2

    2. Completely drain the existing aged oil from the gear unit into an appropriate waste container.

  3. 3

    3. Flush the gearbox thoroughly with a compatible flushing oil to remove sludge and contaminants from internal surfaces.

  4. 4

    4. Refill the gearbox with new, manufacturer-specified lubricant (e.g., ISO VG 220 synthetic gear oil) to the correct level.

  5. 5

    5. After oil change, reset the oil aging sensor or system counter (e.g., via parameter P4-55 in the drive) and verify fault clearance.

Ver todos los códigos en este manual (50)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

SEW Eurodrive 103 Oil aging/fault Display error: Diagnóstic… | ErrorLib