USF
UNDERVOLTAGE
Schindler · Altivar 312 Drive
¿Qué significa USF ?
This fault indicates insufficient line supply voltage, a transient voltage dip, or a damaged precharge resistor. The drive trips if the line voltage drops below specific thresholds: 160V for ATV312 M2/M3 models, 300V for N4 models, and 430V for S6 models.
Causas comunes
- Insufficient line supply voltage to the drive.
- A transient voltage dip (brownout) on the power line.
- Damage to the internal precharge resistor of the drive.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Measure the incoming line voltage at the drive's input terminals and verify it meets the drive's specifications, considering the tripping thresholds (160V for M2/M3, 300V for N4, 430V for S6).
- 2
If the precharge resistor is damaged, the drive may need to be replaced.