ObF
DC bus overvoltage
Schindler · Altivar 312 Drive
¿Qué significa ObF ?
This fault indicates that the DC bus voltage within the drive has exceeded its safe operating limits, often referred to as "overbraking." This usually happens when the motor regenerates energy back into the drive during deceleration, and there's no braking resistor to dissipate it.
Causas comunes
- Motor decelerating too rapidly, regenerating energy into the DC bus.
- Lack of or insufficient braking resistance to dissipate regenerated energy.
- Excessive line voltage, contributing to a high DC bus voltage.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Increase the deceleration ramp time ([Deceleration] (dEC) or [Deceleration 2] (dE2)) to reduce regenerative energy.
- 2
Install or verify the sizing and connection of a dynamic braking resistor.
- 3
Ensure the braking unit, if present, is functioning correctly.