bLF

BRAKE CONTROL FAULT

Schindler · Altivar 312 Drive

¿Qué significa bLF ?

This fault indicates an issue with the brake control system, where the brake release current may not have been reached or the brake engage frequency threshold ([Brake engage freq] (bEn)) is incorrectly set or not assigned despite brake control ([Brake assignment] (bLC)) being active. This can lead to improper motor braking or starting.

Causas comunes

  • Brake release current not reached
  • Brake engage frequency threshold ([Brake engage freq] (bEn)) = [No] (not set) whereas the brake control ([Brake assignment] (bLC)) is assigned

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the drive/motor connection.

  2. 2

    Check the motor windings.

  3. 3

    Check the [Brake release I FW] (Ibr) setting in the [APPLICATION FUNCT.] (FUn-) menu, page 85.

  4. 4

    Apply the recommended settings for [Brake engage freq] (bEn), pages 84 and 85.