SOUt
PM Motor Step-out (Permanent Magnet Motor Pulls Out of Synchronism)
Schindler · Altivar 212 Variable Frequency Drive
¿Qué significa SOUt ?
This fault occurs in permanent magnet motors when the motor pulls out of synchronism, often due to a jammed motor, output phase loss, or sudden impact loads, leading to uncontrolled rotation.
Causas comunes
- The permanent magnet motor is jammed.
- Output phase loss to the motor.
- Sudden impact load on the motor.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the mechanical load and correct any jammed conditions.
- 2
Check the condition of the motor windings and load wiring for integrity.