EEP2

EEPROM Error 2 Fault

Schindler · Altivar 212 Variable Frequency Drive

¿Qué significa EEP2 ?

This fault occurs if power was removed from the Altivar 212 drive during a parameter reset operation, leading to a data writing error in the EEPROM. It can also indicate issues with initial position detection or motor inductance during auto-tuning.

Causas comunes

  • Power removed from the drive during a parameter reset operation, causing a data writing error.
  • Measured current at initial position detection during auto-tuning is too small or large according to the motor's inductance or output phase loss.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Cycle power to the drive to clear the detected fault.

  2. 2

    Attempt the parameter reset operation again.

  3. 3

    If the detected fault persists after re-attempt, contact Schneider Electric to repair the drive.