Low Acceptance

Low Coin Acceptance Rate

Otis · 400 Elevator

¿Qué significa Low Acceptance ?

Indicates a low coin acceptance rate, specifically that more than 20% of the last 255 coins processed were identified as slugs. This suggests issues with coin validation or slug detection.

Causas comunes

  • High percentage of rejected coins (slugs) by the coin acceptor.
  • Malfunction of coin validation sensors or algorithms.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the coin acceptance mechanism's physical chute, sensors, and coin path for obstructions, dirt, or damage.

  2. 2

    Verify the power supply voltage to the coin validation module according to the manufacturer's specifications.

  3. 3

    Check all cabling and connectors between the coin validation module and the main elevator control system for secure fit and integrity.

  4. 4

    Verify the coin acceptance parameters (e.g., coin denominations, acceptance thresholds) in the elevator's system configuration or HMI.