Bill Val Comm

Bill Validator Communication Loss

Otis · 400 Elevator

¿Qué significa Bill Val Comm ?

Indicates no communication with the bill validator for more than 5 seconds. This issue prevents the machine from accepting banknotes, making it inoperable for cash transactions.

Causas comunes

  • Loss of communication between the controller and the bill validator for more than 5 seconds.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect all physical communication cables between the bill validator and the host control system for damage, proper seating, and secure connections.

  2. 2

    Verify the supply voltage at the bill validator's input terminals against the manufacturer's specified nominal voltage.

  3. 3

    Check the communication parameters (e.g., baud rate, device address, protocol settings) in the host control system to ensure they match the bill validator's configuration.

  4. 4

    Observe any status indicator LEDs on the bill validator itself to assess its power status and internal communication state.

Ver todos los códigos en este manual (41)