37810000 hex
Process Data Object Setting Missing
Omron · NJ/NY-series NC Integrated Controller
¿Qué significa 37810000 hex ?
A minor fault indicating incorrect Process Data Object (PDO) mapping within the CNC Function Module for a CNC coordinate system. This fault is detected at instruction execution. While the user program continues, operations for the relevant CNC coordinate systems are not possible.
Causas comunes
- Required Process Data Objects (PDOs) for the CNC instruction are not correctly mapped.
- A CNC instruction was executed for a device that lacks the necessary object support for that instruction.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify and correct the PDO mapping for the specific CNC instruction in use, ensuring all required PDOs are configured and mapped.
- 2
Consult the device manual to confirm whether the device supports the specific CNC instruction being executed.
- 3
Modify the CNC program to ensure that only supported instructions are executed on the target device.