183A0000
Non-volatile Memory Data Error
Omron · NJ/NX-series Machine Automation Controller
¿Qué significa 183A0000 ?
Corrupted data was detected in the non-volatile memory. This error typically occurs if power is interrupted or significant electrical noise is present during critical data saving operations, such as parameter storage or motor identity information.
Causas comunes
- Power interruption during saving of non-safety parameters
- Electrical noise during saving of non-safety parameters
- Power interruption during saving of motor identity information
- Electrical noise during saving of motor identity information
- Power interruption during saving of safety parameters
- Electrical noise during saving of safety parameters
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the stability of the power supply to the Controller, checking for interruptions or sags.
- 2
Check system grounding and shielding to mitigate electrical noise during data saving operations.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Omron NJ/NX-series Machine Automation Controller