Traduciendo...
18230000
Absolute Encoder Multi-rotation Counter Error
Omron · NJ/NX-series Machine Automation Controller
¿Qué significa 18230000 ?
The absolute encoder's multi-rotation counter detected an error, indicating a discrepancy in its tracking of motor rotations. This can be caused by environmental factors or an internal encoder malfunction.
Causas comunes
- Temporary error in encoder multi-rotation detection function due to vibration
- Temporary error in encoder multi-rotation detection function due to impact
- Temporary error in encoder multi-rotation detection function due to condensation
- Absolute encoder hardware failure
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the encoder mounting for excessive vibration or impact.
- 2
Check for signs of condensation or moisture near the encoder.
- 3
Verify the encoder's operational environment against specifications.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Omron NJ/NX-series Machine Automation Controller