Traduciendo...
08440000 hex

Overspeed Error

Omron · NJ/NX-series Machine Automation Controller

¿Qué significa 08440000 hex ?

The encoder detected the overspeed. This means the motor rotated at a speed exceeding its operational limits, which can lead to mechanical stress or system instability.

Causas comunes

  • The motor was rotated by external forces
  • Encoder failure and false detection

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify maximum speed settings, scaling factors, and acceleration/deceleration parameters within the Omron NJ/NX controller and the connected servo drive.

  2. 2

    Inspect all encoder cabling and connections between the motor, servo drive, and Omron NJ/NX controller for physical damage, proper shielding, and secure termination.

  3. 3

    Monitor the actual motor speed feedback from the encoder and the commanded speed signal via the Omron NJ/NX diagnostic interface to identify any discrepancies or erratic behavior.

  4. 4

    Inspect the mechanical load and coupling connected to the motor for signs of binding, reduced resistance, or external forces that could contribute to uncontrolled acceleration.

Ver todos los códigos en este manual (96)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Omron NJ/NX-series Machine Automation Controller