Traduciendo...
F839
Communication Impossible (No Link Parameters)
Mitsubishi Electric · MELSEC Q-series MELSECNET/H
¿Qué significa F839 ?
Communication is impossible because link parameters are not configured or are invalid, specifically indicated by SW0056 being set to 0. This means the station is likely disconnected from the network.
Causas comunes
- Link parameters are missing or invalid
- SW0056 parameter is set to 0
- The station is disconnected from the network
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review the link parameter settings and ensure they are correctly configured
- 2
Verify the value of SW0056 and ensure it is set appropriately for communication
- 3
Investigate the reason for the station being disconnected from the network
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Mitsubishi Electric MELSEC Q-series MELSECNET/H