1A31H
Command Generation Axis Positioning Address Out of Range
Mitsubishi Electric · MELSEC iQ-R Motion Controller
¿Qué significa 1A31H ?
This minor error indicates that the indirect setting for the positioning address for the command generation axis is outside the acceptable range. The valid range is 0 to (value of [Pr.346] Command generation axis length per cycle - 1). If the address is outside this range, the positioning control will not initiate.
Causas comunes
- Positioning address for indirect setting is configured outside the valid range of 0 to ([Pr.346] Command generation axis length per cycle - 1).
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the value of parameter [Pr.346] Command generation axis length per cycle.
- 2
Adjust the indirect positioning address to be within the range of 0 to ([Pr.346] Command generation axis length per cycle - 1).