Traduciendo...
H/Sink O/Temp
Fin overheat
Mitsubishi Electric · FR-E500 Inverter
¿Qué significa H/Sink O/Temp ?
This fault indicates that the inverter's cooling fin has overheated, activating an internal overheat sensor and stopping the inverter output. This condition signifies either insufficient cooling, high ambient temperatures, or a blocked cooling path, posing a risk of damage to the inverter's power components.
Causas comunes
- Ambient temperature around the inverter exceeds specified operating limits.
- Cooling fins are clogged with dust or debris, restricting airflow.
- Reduced cooling fan effectiveness (though Fan Failure has its own code, general cooling issues can contribute).
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the ambient temperature in the inverter's operating environment is within the manufacturer's specifications.
- 2
Inspect the cooling fins and air intake/exhaust vents for dust, dirt, or other obstructions and clean them thoroughly.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Mitsubishi Electric FR-E500 Inverter