Traduciendo...
GLOBAL DRIVE INIT

Initialization or Communication Error

Lenze · 9300 Series

¿Qué significa GLOBAL DRIVE INIT ?

This status indicates an initialization error or a communication error between the keypad and the controller. It signifies that the drive controller is unable to properly start up or establish communication with its human-machine interface.

Causas comunes

  • Error during the initial power-on sequence of the drive controller.
  • Communication failure between the operator keypad and the controller unit.
  • Incorrect initialization parameters preventing system startup.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the ribbon cable connecting the keypad to the controller is securely seated at both ends.

  2. 2

    Check controller parameters related to communication interface settings (e.g., baud rate, address).

  3. 3

    Perform a power cycle of both the controller and the keypad.

  4. 4

    Ensure the keypad model is compatible with the controller version.

Ver todos los códigos en este manual (145)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas