PR2 (Checksum error in parameter set 2)
Lenze · 9300 Series
¿Qué significa 0073 ?
A checksum error has been detected in parameter set 2. This fault can arise from issues during parameter set loading, interruption during transfer via keypad, or incompatibility between stored parameters and the loaded software version.
Causas comunes
- Power interruption or communication timeout during the saving or loading of parameter set 2.
- Incompatible parameter set 2 file being loaded from a different drive model or firmware version.
- Degradation or fault in the drive's internal non-volatile memory sector assigned to parameter set 2.
- Incorrect or corrupted parameter backup file used for restoring parameter set 2 to the drive.
- User attempting to switch to parameter set 2 (e.g., via P0-95) when the set is incomplete or corrupt.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
1. Re-upload parameter set 2 from a known good backup file using the drive's configuration software.
- 2
2. Verify the drive's firmware version and ensure the parameter set 2 file originates from a compatible drive and firmware.
- 3
3. Perform a drive factory reset (e.g., P0-99 = 1) to clear memory, then carefully reload all parameters, including set 2.
- 4
4. Check the parameter switch control (P0-95) to ensure it is not attempting to activate a corrupt set 2.
- 5
5. If the issue persists, consider replacing the drive's control board as it may indicate a memory fault.