¿Qué significa 11015 ?

The PROFIenergy function is unable to establish a connection with Cabinet Control. This fault typically occurs if Cabinet Control has not been loaded correctly or is malfunctioning, which prevents PROFIenergy functionalities from operating.

Causas comunes

  • PROFIenergy cannot establish a connection to the Cabinet Control module.
  • Network issues preventing PROFIenergy from reaching the Cabinet Control.
  • Cabinet Control module is not powered on, not configured, or malfunctioning.
  • Incorrect network address or port for Cabinet Control.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the system logs and HMI for any other fault messages indicating issues with Cabinet Control's operation.

  2. 2

    Perform a complete system reboot to reinitialize all software components, including Cabinet Control and PROFIenergy.

  3. 3

    If the message persists after reboot, re-install the KUKA system software to ensure Cabinet Control is loaded and functioning correctly.

Ver todos los códigos en este manual (13)