SnsrCableError

Sensor cable interrupted!

Kuka · LaserTech 3.1

¿Qué significa SnsrCableError ?

The connection to a sensor has been interrupted, indicating a physical break or disconnection in the sensor cable. This prevents data transmission from the sensor, leading to a loss of monitoring.

Causas comunes

  • The cable connecting the sensor has been interrupted or damaged.
  • Loose or disconnected sensor cable.
  • Short circuit or open circuit within the sensor cable.
  • Damage to the connector at either the sensor or the control unit.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Physically inspect the sensor cable along its entire length for damage, cuts, or disconnections.

  2. 2

    Verify cable terminations at both the sensor and the controller for secure connections.

  3. 3

    Initiate a program reset command to clear the error state.