LsrProgramCan- cel

Laser program was canceled

Kuka · LaserTech 3.1

¿Qué significa LsrProgramCan- cel ?

The active laser program has been canceled. This can occur if the signal LSRO_LsrReset is set during an active program, or if the signal LSRO_LsrStartStatic is reset before LSRO_LsrStopProgram has been set.

Causas comunes

  • The laser program that was active has been canceled.
  • Manual intervention canceled the laser process.
  • An error condition triggered an automatic cancellation of the laser program.
  • Timeout or completion of a programmed laser sequence.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the state of the LSRO_LsrReset signal during program execution to ensure it is not unintentionally set.

  2. 2

    Check the sequence and timing of LSRO_LsrStartStatic and LSRO_LsrStopProgram signals in the robot program logic.