1105
Positioning monitoring {(Axis number)}
Kuka · KSS 8.3 Operating & Programming Manual
¿Qué significa 1105 ?
This message indicates that positioning monitoring has been triggered for a specific axis, {(Axis number)}. This fault occurs when the actual position of the axis deviates excessively from its commanded target during a positioning move, implying an issue with the axis's ability to reach or maintain its target.
Causas comunes
- Excessive deviation of the actual axis position from the commanded target during a move
- Positioning monitoring limits exceeded for axis {(Axis number)} due to external forces or insufficient motor torque
- Mechanical issues or binding affecting the movement of axis {(Axis number)}
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check for any physical obstructions or mechanical issues affecting the movement of axis {(Axis number)}
- 2
Verify the commanded target positions and trajectory for axis {(Axis number)} to ensure they are achievable
- 3
Examine axis drive parameters related to positioning accuracy and following error for axis {(Axis number)}
Datos técnicos verificados. Última actualización: March 2026