133

Monitoring of the actual velocity

Kuka · KRC2 KSS System Message

¿Qué significa 133 ?

A fault has occurred in the control loop. Possible causes include interchanged motor cables between two axes, an error in axis assignment, a defective power module, or an unmastered resolver. This fault causes maximum braking and inhibits all active commands.

Causas comunes

  • Monitoring of the actual velocity has detected an anomaly.
  • Actual velocity deviates significantly from the commanded velocity.
  • Encoder feedback issues or motor control problems affecting speed regulation.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the motor cable connections to ensure they are correctly assigned and not interchanged between axes.

  2. 2

    Eliminate any detected faults in the control loop or errors in the axis assignment.

  3. 3

    Check the power module for proper operation and replace it if defective.

  4. 4

    If the resolver is unmastered, remaster the robot's resolver.