invalid Gateway Error-Byte Config

Invalid Gateway Error-Byte Configuration

Kuka · KR C4 PROFIBUS

¿Qué significa invalid Gateway Error-Byte Config ?

The configuration of the error status bytes for the devices does not match the overall bus configuration. This suggests a mismatch in how error conditions are reported or interpreted.

Causas comunes

  • Error-byte configuration in the gateway is invalid or not supported.
  • Incorrect bitmask or value set for error reporting in the gateway.
  • Firmware mismatch between gateway and configuration tool.
  • Attempting to configure error reporting beyond device capabilities.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the bus configuration in WorkVisual for consistency in error byte settings and correct if necessary.

  2. 2

    Reconfigure the bus after correcting the configuration.