Stop Due to Field Bus Error
Kuka · KR C4 PROFIBUS
¿Qué significa 2858 ?
The robot controller has entered a stop state because an error occurred on the field bus. This indicates a general issue preventing normal operation over the PROFIBUS.
Causas comunes
- Loss of communication with a critical field bus device (e.g., I/O module, drive).
- Network congestion or packet loss on the field bus.
- Incorrect or missing configuration of a field bus node.
- Physical damage to the field bus cabling or connectors.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the status LED on each field bus node is illuminated green.
- 2
Inspect the field bus cable integrity from the controller to the furthest node.
- 3
Check the field bus termination resistors at both ends of the bus.
- 4
Review the field bus configuration parameters in the controller, specifically the node addresses.
- 5
Measure the signal amplitude on the field bus data lines.
Datos técnicos verificados. Última actualización: March 2026