Ground fault, KPP/KSP (axis)

Kuka · KR C4 extended

¿Qué significa 26105 ?

This fault indicates an overcurrent condition within the power unit, specifically identified as a ground fault. This means there is an unintended current path to ground, often through compromised insulation. This poses a risk of electrical shock, equipment damage, and system shutdown.

Causas comunes

  • Insulation breakdown in the motor cable.
  • Internal motor winding insulation breakdown causing a short to ground.
  • Faulty KSP (Kinematic Sensor Package) component.
  • Faulty KPP (Kinematic Power Package) component.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check motor cable for damage to insulation.

  2. 2

    Check motor windings for insulation breakdown to ground (e.g., using a megger).

  3. 3

    Reinitialize the drive bus: Power Off / Power On.

  4. 4

    Check KSP module for faults.

  5. 5

    Check KPP module for faults.