26043

Unknown status flag received, KPP/KSP (axis)

Kuka · KR C4 extended

¿Qué significa 26043 ?

The EtherCAT master has received an unknown status flag from the KPP or KSP module for a specific axis, indicating a software error within the EtherCAT master. This suggests an unexpected communication state.

Causas comunes

  • Software error in the EtherCAT master.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect all EtherCAT cables and connectors for the affected KPP/KSP axis module for damage, secure connection, and proper shielding.

  2. 2

    Verify the operational status and any fault indicators (LEDs/display) on the specific KPP/KSP module for the affected axis.

  3. 3

    Check the EtherCAT master configuration within the Kuka controller software for correct slave addressing and data mapping for the KPP/KSP module.

  4. 4

    Perform a controlled power cycle of the entire Kuka KR C4 controller system to reset all EtherCAT components.

  5. 5

    Review the Kuka system logs and EtherCAT master diagnostics for additional error messages or communication statistics specific to the unknown status flag.