Kuka KR C4 DeviceNet
12 códigos de falla documentados
Error opening 'ecatms_sys_X44_swap.xml'
The file 'ecatms_sys_X44_swap.xml', which is critical for DeviceNet configuration, contains syntax errors. This prevents the system from correctly parsing or loading the configuration, leading to a DeviceNet master configuration error (Message 4429).
IODataCreate() Error
This is a system error related to the IODataCreate() function, impacting the DeviceNet master configuration (Message 4429). This indicates a problem with data object creation within the system.
Invalid ECatWrapper interface
This is a system error indicating an issue with the ECatWrapper interface, leading to DeviceNet master configuration problems (Message 4429). This implies a fundamental software component is not functioning correctly.
System Manager interface invalid
This is a system error indicating an invalid System Manager interface, affecting the DeviceNet master configuration (Message 4429). The system's management interface is not properly initialized or configured.
Multiple Gateways Found
More than one identical gateway module has been detected on the bus. The system supports a maximum of one master and one slave gateway, and this redundancy causes a DeviceNet master configuration error (Message 4429).
Invalid Gateway Error-Byte Config
The error status bytes of the devices do not match the current bus configuration or the topology of the Extension Bus. This indicates a mismatch in how error states are reported or interpreted, causing a DeviceNet master configuration error (Message 4429).
Invalid Gateway PDO-Config
No valid process data object (PDO) configuration is available for the gateway module. This prevents proper data exchange over DeviceNet and results in a DeviceNet master configuration error (Message 4429).
Invalid Gateway-ID
The gateway module's identifier (ID) is unknown or not recognized by the system. This leads to a configuration error (Message 4429) as the system cannot properly identify or initialize the gateway.
Invalid Optional Slave Configuration
The 'ecat_DNM_Gateway.xml' file, which contains the optional slave configuration, is faulty. This prevents the correct setup of optional DeviceNet slave devices and causes a DeviceNet master configuration error (Message 4429).
Unable to Allocate Gateway Memory
This is a system error indicating that the gateway module was unable to allocate necessary memory. This prevents its proper operation and leads to a DeviceNet master configuration error (Message 4429).
Unable to Create Gateway-SEM
This is a system error preventing the creation of the Gateway-SEM (System Event Manager) component. This failure leads to DeviceNet master configuration problems (Message 4429) as critical gateway management resources cannot be initialized.
Unable to Spawn Gateway Task
This is a system error indicating that the gateway task could not be initiated or created, which is essential for DeviceNet master operation and configuration (Message 4429). The gateway's core functions cannot be started.