26130

Intermediate circuit charging failed, KPP/KSP (axis)

Kuka · KR C4 Controller

¿Qué significa 26130 ?

This fault indicates a failure in the charging process of the intermediate circuit within the KPP/KSP drive. This prevents the DC link from reaching its nominal voltage, disabling the power stage and preventing motor operation.

Causas comunes

  • Faulty or disconnected intermediate circuit cabling

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the intermediate circuit cabling for proper connection and damage.

  2. 2

    Reinitialize the drive bus by cycling Power Off / Power On.

  3. 3

    Check the KSP module for any status indicators.

  4. 4

    Check the KPP module for any status indicators.