Traduciendo...
26041
Motor phase failure, KPP/KSP (axis)
Kuka · KR C4 Controller
¿Qué significa 26041 ?
This fault signals a failure in one or more motor phases connected to the KPP or KSP drive. This typically indicates an open circuit or imbalance in the motor's electrical connection or windings, which can lead to motor malfunction or damage.
Causas comunes
- Damaged or disconnected motor cable
- Internal fault or winding damage within the motor itself
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the motor cable for physical damage, loose connections, or breaks.
- 2
Check the motor's windings for continuity and insulation resistance.
- 3
Reinitialize the drive bus by cycling Power Off / Power On.
- 4
Check the KSP module.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Kuka KR C4 Controller