Traduciendo...
Heat sink temperature PMx
KPS Heat Sink Overtemperature
Kuka · KR C2 Robot Controller
¿Qué significa Heat sink temperature PMx ?
An overtemperature condition has been detected on the heat sink of the KPS module (PMx). This indicates that the cabinet ventilation is not functioning correctly, leading to inadequate cooling of the KPS.
Causas comunes
- Ambient temperature in the cabinet is too high.
- Insufficient cooling for the KPS heat sink (blocked vents, fan failure).
- Drive operating at peak load for extended periods.
- Oversized motor or drive operating inefficiently.
- Faulty temperature sensor on the heat sink (P6-01).
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the cabinet cooling circuit and fans for proper operation and sufficient airflow.
- 2
Verify that cabinet air filters are clean and not obstructed.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Kuka KR C2 Robot Controller