Traduciendo...
Drives error Ax no.: 105

KSD Control Unit Device Set Checksum Error

Kuka · KR C2 Robot Controller

¿Qué significa Drives error Ax no.: 105 ?

A checksum error has occurred in the control unit device set of the servo drive module for the specified axis (Ax). This indicates data corruption in the control unit's configuration.

Causas comunes

  • Checksum error detected in the device set of the KSD control unit.
  • Firmware corruption in the KSD control unit's device set.
  • Memory integrity issue within the control unit.
  • Faulty storage medium for the device set.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the KSD module for visible damage or loose connections.

  2. 2

    Restart the controller.

  3. 3

    If the error persists after restart, exchange the KSD module.

Ver todos los códigos en este manual (58)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas