Traduciendo...
Check battery PMx

KPS Buffer Battery Undervoltage (U<19V)

Kuka · KR C2 Robot Controller

¿Qué significa Check battery PMx ?

The buffer battery voltage for the KPS module (PMx) has dropped critically low, below 19V, indicating a severe undervoltage condition that likely requires battery replacement.

Causas comunes

  • KPS buffer battery voltage dropped below P0-51 threshold (e.g., <19V).
  • Faulty KPS buffer battery requiring replacement.
  • Inadequate charging current supplied to the KPS buffer battery.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Charge the battery.

  2. 2

    Exchange the battery.

  3. 3

    Manually save the mastering data via KUKA HMI (`Setup > Master > Save current data`) before battery exchange.

Ver todos los códigos en este manual (58)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas