80
PR6-Trip (Communication error with EEPROM in the power unit)
Kuka · KR C2 Robot Controller
¿Qué significa 80 ?
This fault indicates a communication error with the EEPROM (Electrically Erasable Programmable Read-Only Memory) located in the power unit (KSDs). This prevents the power unit from correctly storing or retrieving its specific configuration and operational data, potentially affecting power stage control and overall drive functionality.
Causas comunes
- EEPROM data corruption in the power unit.
- Communication bus failure between controller and EEPROM.
- Defective EEPROM module.
- Power fluctuation during EEPROM read/write operations.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Perform a power cycle of the drive's power unit to attempt to re-establish communication.
- 2
Check for any visible damage or loose connections to the power unit's internal memory module, if accessible for inspection.
- 3
Attempt to re-upload the power unit's specific configuration data from a valid source.
Datos técnicos verificados. Última actualización: March 2026