Traduciendo...
79
Pr5-Trip (Communication error with EEPROM in control unit)
Kuka · KR C2 Robot Controller
¿Qué significa 79 ?
This fault indicates a communication error with the EEPROM (Electrically Erasable Programmable Read-Only Memory) located in the control unit, affecting both KPS-600 and KSD devices. This can lead to issues saving or retrieving critical operational data and parameters, potentially causing incorrect device behavior or preventing startup.
Causas comunes
- Pr5-Trip: Communication error with EEPROM in the control unit (P1-13).
- Corrupted data in the control unit's EEPROM.
- Loose connection to the EEPROM module.
- Failed EEPROM chip.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Perform a power cycle of the control unit to attempt to re-establish communication.
- 2
Check for any visible damage or loose connections to the control unit's internal memory module, if accessible for inspection.
- 3
Attempt to re-upload the control unit's configuration data from a valid source.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Kuka KR C2 Robot Controller