Alarm Space 8 Violation
Kuka · KK53Y Servo Motor
¿Qué significa MR8 ?
The MR8 signal indicates a violation of monitoring space 8. A '0' state on this signal means that monitoring space 8 is currently being infringed upon. If monitoring space 8 is intentionally inactive, the system considers it violated by default, and the associated safe output MR8 will be in the '0' state.
Causas comunes
- Alarm condition triggered in Space 8 of the monitoring system.
- Parameter P8 has exceeded its defined alarm threshold.
- Sensor associated with Space 8 reporting an out-of-bounds value.
- Configuration error in Space 8 alarm limits.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Identify the configured boundaries for monitoring space 8 in the robot's programming environment (e.g., using KUKA WorkVisual).
- 2
Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 8.
- 3
If monitoring space 8 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR8 signal will default to a '0' (violated) state.