Traduciendo...
MR4

Alarm Space 4 Violation

Kuka · KK53Y Servo Motor

¿Qué significa MR4 ?

The MR4 signal indicates a violation of monitoring space 4. A '0' state on this signal means that monitoring space 4 is currently being infringed upon. If monitoring space 4 is intentionally inactive, the system considers it violated by default, and the associated safe output MR4 will be in the '0' state.

Causas comunes

  • Alarm condition triggered in Space 4 of the monitoring system.
  • Parameter P4 has exceeded its defined alarm threshold.
  • Sensor associated with Space 4 reporting an out-of-bounds value.
  • Configuration error in Space 4 alarm limits.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Identify the configured boundaries for monitoring space 4 in the robot's programming environment (e.g., using KUKA WorkVisual).

  2. 2

    Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 4.

  3. 3

    If monitoring space 4 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR4 signal will default to a '0' (violated) state.

Ver todos los códigos en este manual (17)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas