1078

VACC NOT OK

Kone · Elevator Control

¿Qué significa 1078 ?

The motor controller (codes 1078, 2078, 3078) has detected that the accessory voltage (VACC) is not within acceptable limits. This indicates a problem with the auxiliary power supply. The specific lift reaction is controller dependent.

Causas comunes

  • Auxiliary power supply fault (e.g., overvoltage, undervoltage).
  • Short circuit on an accessory output drawing excessive current.
  • Internal power supply regulation fault within the controller.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the main input voltage supply to the auxiliary power supply unit for proper phase and magnitude.

  2. 2

    Measure the VACC output voltage from the auxiliary power supply at the motor controller's VACC input terminals.

  3. 3

    Inspect all wiring and connections between the auxiliary power supply unit and the motor controller for damage, looseness, or corrosion.

  4. 4

    Check relevant diagnostic parameters within the Kone elevator control system for any additional fault details or specific VACC threshold settings.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026