08

Key Switch Error

Kone · Elevator Control

¿Qué significa 08 ?

An error is detected with the machine's key switch, indicating a malfunction in its electrical circuit or physical state. This is a warning only.

Causas comunes

  • Malfunction of the key switch (e.g., stuck, open, shorted contacts).
  • Damaged wiring or loose connections to the key switch.
  • Incorrect voltage detected on the key switch input.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the physical key switch for any visible damage, wear, binding, or debris that might prevent proper mechanical operation.

  2. 2

    Check all wiring connections associated with the key switch, from the switch itself to the main control board, for looseness, corrosion, or damage.

  3. 3

    Verify the electrical state (e.g., continuity, voltage level) of the key switch input signal at the Kone Kone Elevator Control board, using the provided wiring diagrams, to confirm the switch signal is correctly reaching the controller.

  4. 4

    Confirm the correct key is being used and is fully inserted and rotated to the designated operational position according to the elevator's operating instructions.