CAN Communication Fault

Kone · CMXC-022 Frequency Control Upgrade Kit

¿Qué significa 53 ?

A fault in the CAN communication has been detected, indicating that the CAN bus is not functioning correctly. This can be due to power issues, incorrect wiring, improper termination resistor settings, or misconfigured CAN-communication parameters.

Causas comunes

  • CAN communication not working properly
  • Incorrect CAN-bus wiring or termination resistor settings
  • Incorrect CAN-communication parameters

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Switch off the supply voltage from all devices connected to the CAN bus

  2. 2

    Check the CAN-bus wiring and the termination resistor settings

  3. 3

    Verify the CAN-communication parameters for correctness