Invalid Status #
Indramat · ServoDyn D Servo Drive
¿Qué significa RS 09 ?
This serial communication error occurs if the status number being transmitted to the CLM01.3-M is invalid, meaning it is not included in the list of defined status numbers in Chapter 7, Serial Interface. The CLM01.3-M cannot process requests for non-existent status numbers.
Causas comunes
- The status number requested in the serial command is not a valid or defined status number for the CLM01.3-M.
- Typographical error in the status number during transmission.
- Attempting to request a status that is not implemented in the CLM01.3-M firmware.
- Sending device software attempting to read an incorrect or outdated status number.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that the status number being transmitted to the CLM01.3-M is a valid status number listed in Chapter 7 (Serial Interface).
- 2
Correct the status number in the transmitted serial command to a recognized value.
- 3
Check the serial communication link for data corruption or unusual characters.
- 4
Re-transmit the status request after correcting the status number.
- 5
Ensure the sending device's software uses the correct and up-to-date list of status numbers for the CLM01.3-M.